Inspection and maintenance of welding machines

Maintenance

  • Regularly check and record test results Check the level and humidity of the coolant in the transformer. Check for debris Various metal powder Leakage current The environment is at the right temperature. Not too hot or crowded
  • Prevents overheating. Check with a dynamometer to ensure that the magnitude of the applied current does not exceed the rating of the welding machine and the welding cable.
  • Tools are kept clean. Do not modify the condition of the device or the equipment.
  • Be sure that the welding machine has built-in vent and cooling fans. And must work

 

Practice for welders

  • Must check the external connection cable every day. Make a note and report any irregularities in the welding harness. And related equipment such as welding electrodes, wire grips Or device header, welding cable, heat insulation caused by size or other defect
  • Make sure that the cable connections are always tight and that the contacts are clean.
  • Check the condition of the welding cable and ground. Not to cause damage or leak
  • Use it correctly Do not modify the welding machine, welding cable or other parts. If there is any damage to the equipment To immediately change
  • Welding using very high current The power cord must be of the type that will withstand the highest current for use.
  • If the machine has a problem Or there is something wrong Should stop the machine And notify the relevant departments to promptly repair

 

Check the welding harness

  • Loosening of welding chucks, or other head devices
  • Burns or cracks in the device
  • Overheating And cable damage And a set of welding head equipment
  • Secure the ground wire to the workpiece with the workpiece holder (Ground Clamp) and with the appropriate power size such as 300 amps, 500 amps, etc.
  • Make sure that the power cable, either grounded or welded, can withstand the maximum operating current.

 