Correct storage of chemicals

The most convenient and most common method is Alphabetize But such a arrangement may cause substances that should not be in close proximity to each other to be kept together. Which may explode or release toxic gas at any time So how to store chemicals in alphabetical order? Therefore it is not a safe way to store chemicals Another way is The same chemical fire extinguishing method together To facilitate the use of fire extinguishers when there is a fire. But just like the first one, it brings together incompatible substances.

Best way Is to classify chemicals according to the reactivity And designate incompatible substances Place it separately and keep it away from each other. The thousands of chemicals in use can be divided into six groups:

– flammable chemicals
– explosive chemicals
– toxic chemicals
– corrosive chemicals
– radioactive chemicals
– inaccessible substances (incompatible chemicals)

Usually, the storage of all kinds of chemicals There will be general principles as follows

  1. The storage location should be a closed place. Outside the building Wall cladding should be made of flame retardants (fire resistant), lockable
    and clearly labeled. “Chemical storage locations”
    2. Within the chemical storage locations It should be cool and dry. Have good ventilation system And the sun does not shine.
    3. Chemical shelves within the chemical storage location must be stable, strong, no vibration.
    4. Containers containing chemicals. Must have a durable label that is thought to be along with the dangers and cautions.
    5. Containers must be resistant to pressure. Corrosion and external shocks There should be a spare container. In case of
    Cracking or leaking containers can be replaced immediately.
    6. Large and heavy storage containers should not be stored in high places. In order to be more convenient to use.
    7. Bottles should not be placed directly on the floor. Or should not place the spoon on the other bottle. And there is a reasonable distance between the storage layer
    Should not place the substance in the narrow path. Or near the door or window.
    8. The substance should be stored in the order of entering first after. And must be used before expiration If expired, must be destroyed immediately.
    Do not use is strictly prohibited.
    9. Chemical should be separated in small quantities. Using small containers The storage area should be kept clean.
    And to be in a regular order And a systematic arrangement.
    10. Must have fire fighting equipment. Safety equipment And first aid equipment ready in the event of an emergency

In general, when the properties of a substance are known, it can be determined how it is, for example a liquid with a low freezing point. Must be stored at a temperature higher than that. Because when the substance freezes Volume will increase Which might break the bottle And it is very dangerous that some substances must use a inhibitor to prevent them from exploding. If the coagulant separates from the inhibitor to become pure substance When the substance is molten again, it will explode such as acrylic acid. In addition to determining the chemical storage according to the sensitivity in the reaction. Chemical incompatibilities, such as galcial acetic acid, must also be considered.It is a chemical that ignites and explodes when exposed to oxidizing acid such as nitric acid, perchloric acid or strong sulfuric acid.Therefore, acetic acid should be kept away from oxidizers. Not the same acids can be stored together.There are many types of chemicals that we need to pay special attention to:

  • Acids (acids) bases
  • Flammables
  • Oxidizers
  • Water reactive chemicals
    pyrophoric substances
  • Light-sensitive substances (light-sensitive chemicals)
  • Substances that will form peroxides (peroxidizable compounds)
  • And toxic compounds, etc.

Each substance has a method for its safe storage according to its properties.

Flammable materials. Typically,
combustion occurs between oxygen and fuel in a vapor form. Or small mist, so volatile substances with high vapor pressure are easily flammable. Flammable chemical particles or dust can be ignited as easily as gaseous or vaporous substances. Flammable substances under normal temperature and pressure conditions. Are considered flammable Examples of these are metal fine powders.
Hydro of boron, phosphorus, liquids with a flash point below 30 degrees and various flammable gases.

– Store in a cool, ventilated place. And away from ignition sources such as heat, sparks or open flames.
– Keep in a safe container. Or flammable storage cabinets, which have been verified to be safe Storage containers must be tightly closed to allow
airtight.
– Separated from oxidizers, spontaneous combustibles. Explosive substances and substances that react with air or moisture.
And gives out a lot of heat.
– There is no smoking sign. Or do not ignite matches
– the area should be plugged into the ground to reduce the possibility of static electricity.

Incompatible substances
Incompatible materials Incompatible materials are substances that, when approached, react violently. Explosion Generates heat or allows toxic gases to be released They must be stored separately, as far as possible, eg water-sensitive storage – must be stored in a cool, dry place. Far from water

– Prepare a class D extinguisher in case of fire oxidizers – Keep away from fuels. And combustible materials
– keep away from reducing agents such as zinc, alkaline metal or formic acid.

Danger of toxic substances (toxic hazards)
toxic chemicals are substances that are harmful to living organisms under any conditions. This will include radioactive substances. (radioactive) with storage

– The container must be closed tightly. Air is not accessible
– away from a source of ignition
– routine inspection. Both the container and the storage area of ​​the substance.
– Substance sensitive. Must be kept in an amber colored bottle In a cool, dry and dark place

Corrosive materials Corrosive materials
include acids, acid anhydride, and alkalis. They tend to destroy the container and enter the atmosphere outside. Some are volatile, some react violently with moisture.

– Keep in a cool place But must be higher than the freezing point.
– Use gloves, goggles, etc. When using these substances
– Acids must be kept away from reactive metals such as sodium, potassium and magnesium, etc.
– alkalis must be kept from acids and other substances. Reactive

Explosives
are substances which at a certain temperature are rapidly decomposed in response to vibration or violent reactions. Will give out a lot of gas Including heat Which makes the air around The cause of rapid expansion As a result, an explosion can occur. The effects of the explosive substance are extreme heat or cold, dry air or rising in storage. Carelessness in handling, storage time Time taken from the original container before use
for storage.

– Keep away from other buildings
– Tightly locked
– Do not store in the fuel. Or flammable substances.
– At least 20 feet away from the flame
– should not contain explosives. (detonators), tools and other substances included
– should not be stacked more than 6 feet apart
– must be transported with care
– no one can enter the container.

Description of chemical warehouse
Location
– a good chemical storage location. Should stay away from areas with high density of people. Far from sources of drinking water Far from the flooded area And away from other dangerous sources That may arise from outside the warehouse
– the warehouse location There should be easy routes for transportation and management in emergencies
– Adequate facilities such as emergency power supply, fire extinguishing system,

The drainage system prevents the flow of water contaminated with chemicals in an emergency to public water sources with wastewater treatment systems. Due to the water caused by fire fighting Causing environmental problems

Surrounding area
– The area surrounding the site must have a wall or fence that is in a stable condition and can be easily maintained
– there is free space along the wall or fence. For separate storage of spilled chemicals And to provide operations in mitigating the dangers of spilled chemicals
– security guards are available at night and providing safety equipment such as ambient lighting. Building Plots
– Building plans must be designed so that incompatible substances can be stored. By using separate buildings Use of fireproof walls Or other protection, such as designed to have enough space that can be moved. Safe handling of chemicals
– Chemical storage buildings must be spaced apart from each other
– location and building. There is protection against intruders by building a fence. There is a door in – out. With measures to prevent arson

Chemical storage building design
Building plans must be designed in accordance with the type of chemicals to be stored. Which has adequate preparation for emergency exits The area and area of ​​the chemical storage building must be limited. By dividing into rooms or in proportion In order to store different types of hazardous substances and those that cannot be collected together, the building must be completely enclosed. And lockable Building construction materials are non-flammable. And building structures are reinforced concrete or steel If it is a steel structure, it must be insulated.

Building walls
– exterior walls must be strong. And should be covered with steel or metal sheet To prevent the fire from outside the building
– inner walls designed to be a wall of fire Fire for 60 minutes and the height above the roof of one meter or other methods that could prevent the group spread of fire
– material. Used as insulation of buildings are non-combustible types such as metal fibers or glass fibers
– materials suitable for fire resistance. And has strong and durable properties: concrete, brick or reinforced concrete block The thickness should be at least 15 centimeters or 6 inches and walls at least 23 centimeters or 9 inches thick to withstand fire. If it is a hollow brick, it is not appropriate to use ordinary concrete. Must be at least 30 centimeters or 12 inches thick for strength and durability. To make the structure strong, reinforced concrete columns must be built in the fireproof wall.
Fireproof wall, fireproof wall It should be free from other structures to prevent erosion. When there is a fire Plumbing, conduit and fire wall wiring installation They must be placed in the sand to prevent fire. Floor
– Building floor must not absorb liquids.
– Building floor must be smooth, smooth, free of cracks. Easy to clean
– The floors must be designed to contain spilled chemicals. And water from fire fighting By the way of making a sill border or a border around

Roof
– The roof must be rainproof. And designed to be ventilated for smoke and heat During Fire
– Materials used for roof construction do not require special fire protection types, but
woodshould not beused because of the risk of fire spreading. The structure supporting the roof must be made of non-combustible materials. Can use hardwood When the roofing material is not flammable Because wooden beams provide longer structural strength than steel beams in the event of a fire
– roofing materials can be lightweight and collapse easily in the event of a fire.
To help exhaust the smoke and heat away But if the roof is strong, ventilation holes must be provided. To provide ventilation, smoke and heat at least 2% of the roof area.
– The vents must be permanently open and can be opened by hand. Or open by itself when there is a fire Exhausting smoke and heat will help to see the source of the fire and help slow down the spread of the fire.

Fire
Doors Fire doors will consist of
– a fusible interlock. Installed over the top of the door Heat or flames raging from chemical storage areas Will pass along the wall to trigger the chain
link – The counterweight has a cable that passes through the weight and the counterweight is not fixed
in place. Of fireproof doors They must have the same fire resistance as the walls of the building and be able to close automatically, such as having a fusible interlock. They are automatically triggered by the smoke detectors and the doors will close automatically in the event of a fire. Caution There must be space for the door to be closed. There are no obstructions.

Emergency exit
– An emergency exit must be provided. Apart from the normal entrance-exit Planning for an emergency exit All emergencies that may arise must be considered. The most important thing is No one must be trapped in the building to collect hazardous substances.
– Mark the emergency exits clearly by adhering to safety principles
– Emergency exits must be easily opened in the dark or when heavy smoke is poured.
– Emergency exits For escaping the fire from various areas At least two directions
must be provided. Ventilation – Good ventilation with regard to the type of chemical stored And satisfactory and safe working conditions
– adequate ventilation This occurs when the vents are positioned on the roof. Or building walls in the lower part from the roof And near the ground

Drainage
culvert open is not suitable for the storage of chemicals that are toxic. To prevent contamination from spilled chemicals And water from the fire fighting flows into public water sources Rainwater drains must be outside the building. Indoor drains must be of non-combustible type.

Lighting and electrical equipment

  • Chemical and hazardous materials storage buildings that operate in daylight and with adequate natural light No need to install lights This principle is accepted and practiced. Because it reduces costs Reduce maintenance And reduce the need to install special electrical equipment But if working conditions where natural light is not enough Lighting conditions must be improved by installing a transparent roof panel.
  • In areas that need lighting and facilities All electrical equipment Including the wiring must be installed in a standard way and maintained by a qualified electrician.
  • Temporary electrical installations should be avoided. But if necessary, it may be installed as standard.
  • All electrical equipment must be installed in a safe location from an accident that can cause damage, such as the use of a forklift, loading and unloading goods or equipment. Also avoid placing electrical equipment or power lines in wet or wet areas.
  • Electrical equipment must be grounded. And properly prepared when there is an overload or when there is a short circuit.
  • In a flammable storage building Or it may cause an explosion, such as a low flash solvent. Or substances with properties that are fine dust that can explode It is very important to use explosion-proof electric equipment and forklift trucks.
  • In chemical and hazardous materials storage buildings, efficient ventilation must be provided.
  • Where the battery charger is used They should be separated from chemical and hazardous materials storage buildings and have good ventilation. However, operations that may generate heat or sparks should be avoided. Except there are special preventive measures

Heat

  • Generally, chemical and hazardous materials storage buildings must have a cool climate. But when it is necessary to maintain the conditions of the hot storage area To prevent the solidified substance The use of the heating system must be without direct heat contact. And it is a safe method such as steam, hot water, hot air, and the heat source must be outside the building where the hazardous substance is stored. Water heaters or steam pipes Must be installed in an area where the heat will not come into direct contact with chemicals and hazardous substances.
  • Do not install devices that generate electricity. Or gas or heat from the burning of oil
  • Installation of insulation Insulating materials must be non-combustible, such as asbestos or glass wool.

Lightning protection
All buildings that store flammable chemicals Must be equipped with a power cable Or it may be exempt if the warehouse is within the radius of the lightning rod of another nearby building.

Other requirements
Should not create an office Dining room Changing rooms are included in the storage building. But if necessary for convenience Such structures must be separated from the hazardous substance storage buildings. And can endure the fire for 60 minutes

Outdoor chemical and hazardous storage
Outdoor chemical and hazardous storage A protective dam must be prepared as well as for chemical storage indoors. And must have a roof to protect from sunlight and rain

Additional considerations for outdoor storage of chemicals and hazardous materials

  • Chemicals and hazardous materials stored outdoors Especially in hot countries, deterioration must be considered. Due to exposure to high temperatures Therefore, it is important to be careful in selecting the storage method based on the MSDS safety information.
  • To prevent contamination of chemicals and hazardous substances into soil and water, the storage area must be covered with materials that are resistant to water and heat. Do not use asphalt as it will melt easily. When it’s hot
  • The embankment area must be equipped with a water gate drainage control system.
  • Storage chemicals and hazardous materials must be checked for leaks regularly to avoid contamination.
    Into the drainage system
  • Chemicals and hazardous substances stored in 200 liter drums and not sensitive to heat. May be kept out of the open, but must have the same spill protection system as the indoor storage.
  • It is recommended that chemicals and hazardous materials be stored in round drums upright on the product mat. There must be enough free space for each storage tank to extinguish the fire.
  • Chemicals and hazardous materials that are highly flammable liquid, gas or liquid chlorine. Should be kept outside the building

 

Leave a Comment

Scroll to Top